Waste water pipe
|
|
|
|
|
Location:
|
|
Wittnau (Switzerland)
|
|
Assignment:
|
Insulated waste water pipe over a stream, in one section.
Medium and casing pipes were delivered.
Medium pipe: 400mm
Casing pipe: 630mm
|
|
Solution:
|
|
The 20-m pipe sections were pushed into one another, the cavity was insulated with PUR foam and the insulation was sealed on both sides.
|
|